EN ISO 14122-4

Typical application: Ladder for plant machinery maintenance

  • Topmost rung must finish at the same level as the exit platform.
  • From an access height of 10,000 mm, the ladder shall be installed with an off set. The maximum length of a ladder section must not exceed 6,000 mm.
  • The off sets shall be arranged at equal intervals, may, however, be designed at a different height on request or through the online configurator.
  • Distance of the rung-leading-edge of the ladder to the wall must be at least 150 mm.

Exit:

  • According to EN ISO 14122-4, the exit point must meet the highest safety requirements.
  • The exit must be secured with a self-closing barrier, the gap between the ladder and the building shall not be greater than 75 mm.

 

  • The ascent stile must be connected to the exit platform with a 1,500 mm long guardrail on both sides.
  • The guardrail supplied may be omitted if it is possible to connect to a guardrail on the building.

 

Back

 

 

Fastening:

  • The standard wall mounting has a distance between the stile and the building of 210 mm.
  • Other fastening options are available, depending on the distance from the wall.
  • The distance between the individual fastening points shall not exceed 2,000 mm, they shall, however, preferably be mounted beneath the rungs.

Ladder safety cage:

  • Distance from the lowest safety cage clamp to the floor: 2,200 mm to 3,000 mm.
  • Safety cage required from vertical height of 3,000 mm.